Launched at JFR 2026 · read the news → Voxia

The right report.
The right follow-up.

The radiologist’s voice assistant, natively integrated into the TsXcare report editor. You speak, Voxia executes; you decide, always.

Built into the RIS, not a plug-in Local processing, no third-party cloud Your report templates and blocks
Voxia’s avatar
A single gesture

Hold, wait for the beep, speak, release.

Ctrl+Space or the SpeechMike’s rear button: Voxia executes the command and displays what it understood. Dictation has its own shortcut, Ctrl+Shift+Space: a dictated sentence is never mistaken for a command.

Standard phrases recognised in under 0.6 s No wake word Philips SpeechMike
Voice commands

Your report editor obeys your voice.

Report templates, pre-written blocks with their variables, anatomical diagrams, field navigation and formatting: everything you used to do with the mouse, you can now say.

« Introduce yourself »Voxia « Start dictation for Mr Nguyen’s file »RIS « Load the prostate MRI template »Template « Insert the L1-L2 segment description »Block « Insert the prostate diagram »Diagram « Next field »Navigation « Generate the conclusion »Conclusion « Review the report »Review « My reports to sign off »RIS « Show pathology alerts »Follow-up
PI-RADS v2.1 prostate map, right apex TZa sector marked
“Insert the prostate diagram” · “Mark right apex TZa”Sector marked

Diagrams that fill in by voice.

41-sector PI-RADS v2.1 prostate map, lumbar spine, breasts: a named sector is marked and labelled, then the diagram is inserted at the cursor.

Your report templates and block library, managed by the practice
Variables filled in by voice: side, level, size
Conclusion compiled from the sentences you dictated “in conclusion”
RIS tools: my day, reports to sign off, patient search, prior exams
Structured reports

Six modules, current reporting standards.

A diagram where each click places a finding, a controlled lexicon, a live report preview and a “Check” button that lists what is missing before insertion.

BI-RADS v2025 · 2013 Mammography Density, findings placed by clock position on each breast, associated ultrasound, one category decided per breast. « Open the mammography module »
PI-RADS v2.1 Prostate MRI 41-sector map, lesions placed with one click, score per lesion. « Open the prostate module »
EU-TIRADS · ACR TI-RADS Thyroid ultrasound Nodules described lobe by lobe, lymph node map, normal exam in three clicks. « Open the thyroid module »
Fleischner 2017 · Lung-RADS v2022 Pulmonary nodules Context first, then nodules and management according to the selected standard. « Open the pulmonary nodules module »
Bosniak 2019 Cystic renal masses Modality, then guided description of each mass and its class. « Open the Bosniak module »
O-RADS US v2022 · MRI Adnexal masses Ultrasound or MRI, controlled lexicon and O-RADS category decided by the radiologist. « Open the O-RADS module »
4 clicksfor a normal screening mammogram, insertion included
Learning modethe definition of each term on hover
Step-by-step in-app guide, plus a printable PDF version for each module.
New features presented at JFR 2026

It reviews, it formats, it follows up.

It reviews with you Side, organ, terminology: inconsistencies are flagged before signing. Using prior reports, Voxia spots an organ described although it has been removed, a lesion not carried over, or a size that changes without comment. Voxia flags, corrects nothing and never blocks signing.
Automatic formatting Your dictation, organised according to your templates and house style: headings, sections, one sentence per line, conclusion in bold. Each radiologist sets their own formatting. The final text keeps only your words: any change in meaning is rejected.
Voxia handles follow-up Dated management recommendations in structured reports become milestones: follow-up exams, sampling, pathology results. Anything that has not happened is raised as an alert, with reminders and letters to the referring physician. An organisational safety net, with no medical decision-making.
7 mm pulmonary noduleFollow-up CT at 6 months Reminder scheduled
Sovereignty

Your voice does not leave your healthcare system.

The speech recognition is developed by THERA SOFT and runs on dedicated servers, with HDS-certified health data hosting. No more reliance on a third-party dictation service.

—No audio or dictated text is logged —No patient data stored on the compute servers —RIS data accessed through typed routes, with permission checks
Safeguards

The radiologist decides. Always.

A dictated sentence is never interpreted as a command.
Never any image analysis, diagnosis or recommendation that you have not made yourself.
Any text written or modified by the AI stays marked until you have approved it.
Sides, levels, measurements and negations are checked by rules, not by AI.

The classification assistance and assisted drafting functions are undergoing qualification as a medical device (Regulation (EU) 2017/745); they will not be marketed before they are CE marked.

Voxia, on your own reports.

Talk to the team that develops it, in Limoges.